CECC Inspection Levels for Fully Assessed Devices (Discrete)


Group A - Lot by Lot inspection
  IL = inspection levels
AQL = Acceptable Quality Level (%)

Levels of Quality Assessment
  Level E Level F & Level L
Examination or Test IL AQL  Observations IL AQL  Notes
Sub-Group A1
Visual Inspection
I 0.65   I 0.65  
Sub-Group A2a
Non operatives
II 0.15   II 0.15  
Sub-Group A2b
Electrical Measurements
II 0.40  Primary DC Charcateristics II 0.65
1.0
 if < 4 tests
 if ≥ 4 tests
Sub-Group A3
Electrical Measurements
II 0.65  Other DC Characteristics II 2.5
4
 if < 4 tests
 if ≥ 4 tests
Sub-Group A4
Electrical Measurements
S4 1  AC Characteristics S4
S4
4
6.5
 if < 4 tests
 if ≥ 4 tests

Group B - Lot by Lot inspection
  IL = inspection levels
AQL = Acceptable Quality Level (%)
amb = ambient rated
case = case rated AQL in %

c = acceptance criterion
n = sample size
Levels of Quality Assessment
  Level E Level F Level F & Level L
Examination or Test n/c IL AQL IL AQL  Notes
Sub-Group B1
Dimensions
15/0 or 25/1 S2 2.5 S2 2.5  
Sub-Group B2c
Verification of ratings
15/0 or 25/1 S4 4 na na  see C2c
Sub-Group B3
Lead bending if applicable
15/0 or 25/1 S3 2.5 S2 4  
Sub-Group B4
Solderability
22/0 or 38/1 S4 2.5 S4 2.5  
Sub-Group B5
Change of temp followed
by acc. Damp heat or sealing
15/0 or 25/1 S4 2.5 na na  see C5
Sub-Group B8
Electrical endurance
38/1 or 52/2 S4 1.5 na na  see C8
Sub-Group B8
Electrical endurance
 Unless otherwise stated in detail specification: attributes information for B3, B4, B5, B8

Group C - Periodic inspection
  P = periodicity (months)
na = not applied
Levels of Quality Assessment
  E
(p = 3 months)
F
(p = 3 months)
L
Examination or Test n/c Notes n/c Notes P n/c Notes
Sub-Group C1
Dimensions
8/0 or 13/1   8/1   3 8/1  
Sub-Group C2a
Electrical Measurements
15/0 or 25/1   13/1   3 13/1  
Sub-Group C2b
Complementary Characteristics
32/0 or 55/1
15/0 or 25/1
versus T versus I,V 18/1   3 18/1  
Sub-Group C2c
Verification of ratings
15/0 or 25/1   13/1 when not
in B2c
3 8/1  
Sub-Group C3
Tensile/Torque (if applicable)
15/0 or 25/1   8/1   6 8/1  
Sub-Group C4
Soldering heat
22/0 or 38/1   18/1   na na  
Sub-Group C5
Change of temp followed by
acc. Damp heat or sealing
na see B5 na see B5 3 13/1  
Sub-Group C6
Shock acceleration vibration
15/0 or 25/1   8/1   6 8/1  
Sub-Group C7
Damp heat (if applicable)
15/0 or 25/1   18/1   na na  
Sub-Group C8
Electrical endurance
38/1 or 52/1   43/3
34/2
amb
case
3
3
32/3
25/2
amb
case
Sub-Group C9
Storage at high temp
38/1 or 52/2   43/3
34/2
amb
case
na na  
Sub-Group CTR  Unless otherwise stated in detail specification attributes information for C3, C5, C6, C9.
 Measurement information before and after C8