logo
  SEARCH ENGINES
  GO


  THE DIVISIONS
  * POWER
power
  * AEROSPACE
aerospace
  * OPTO
opto
  * RF
rf
  * MAGNATEC
magnatec
 
Inspection Levels for BS
Fully Assessed Devices (Linear)

Group A - Lot by Lot inspection
  IL = inspection levels
AQL = Acceptable Quality Level (%)

Levels of Quality Assessment
Examination or Test IL AQL BS9400  Observations
Sub-Group A1
Visual Inspection
I 1.5 1.2.2  
Sub-Group A2
Non operatives
II 0.15    
Sub-Group A3a
Electrical Measurements
II 1.5    Static Characteristics Tamb = 25°C
Sub-Group A3b
lectrical Measurements
II 1.5    Static Characteristics Tamb = Tmax
Sub-Group A3c
Electrical Measurements
II 1.5    Static Characteristics Tamb = Tmin
Sub-Group A4a
Electrical Measurements
S4 4%    Dynamic Characteristics Tamb = 25°C

Group B - Lot by Lot inspection
  IL = inspection levels
AQL = Acceptable Quality Level (%)

Levels of Quality Assessment
Examination or Test IL AQL BS9400  Observations
Sub-Group B1
Dimensions
S2 6.5 1.2.3  
Sub-Group B2a
Solderbility
S4 4.0 1.2.6.12.1  
Sub-Group B2b
Change of temp followed
by sealing
S4 4.0 1.2.6.13 1.2.6.14.1/2  
Sub-Group B3
Lead bending
S3 6.5 1.2.6.16.2  
Sub-Group B6
Acceleration steady state
S4 4.0 1.2.6.9  
Sub-Group B7
Electrical Endurance
S4 1.5 1.2.7.2.2  
Sub-Group B8
CTR Information
       Unless otherwise stated
 in detail specification: attributes
 information for B2a, B2b, B6, B7

Group C - Periodic inspection
  IL = inspection levels
AQL = Acceptable Quality Level (%)

Levels of Quality Assessment
Examination or Test IL AQL BS9400  Observations
Sub-Group C1
Dimensions
S2 6.5 1.2.3  
Sub-Group C3
Vibration followed by Shock
followed by Damp Heat Cycle
S2 6.5 1.2.6.8.1
1.2.6.6
1.2.6.5
 
Sub-Group C5
Electrical Endurance
S3 4.0 1.2.7.2.2  Duration = 2000 hrs
Sub-Group C6
CTR Information
S3 6.5 1.1.11  Unless otherwise stated in detail
 spec: attributes information for C3 &
 C5

1   PRODUCT LINES
2   TECHNOLOGIES
3   SCREENING &
  QUALIFICATIONS