Level 1 (2)
56 Components |
 |
|
 |
Environmental
Mechanical Subgroups
(16 Components) |
|
Level 2 (2)
40 Components |
 |
|
 |
|
 |
|
 |
| 8 Components |
|
8 Components |
|
Endurance Subgroup
(16 components) |
|
Level 3 (2)
25 Components |
 |
|
 |
|
 |
|
 |
Shock Test
Para 9.3 |
|
Thermal Shock
Para 9.5.2 |
|
Operating Life
Para 9.20.2 |
|
Electrical Subgroup
(25 components) |
 |
|
 |
|
 |
|
 |
|
 |
Vibration
Para 9.14 |
|
Moisture
Resistance
Para 9.16 |
|
Electrical Measurements during Endurance Test
Para 9.9.4 |
|
20 Components (Electrical Measurements) |
|
5 Components (1) (Assembly Capability Tests) |
 |
|
 |
|
 |
|
 |
|
 |
Constant Acceleration
Para 9.15 |
|
 |
|
 |
|
Electrical
Measurements
Room Temp
Para 9.9.3 |
|
Solderability
Para 9.17 |
 |
|
 |
|
 |
|
 |
|
 |
Seal Test
Para 9.8 1/2 |
|
External Visual Inspection
Para 9.10 |
|
Electrical Measurements High & Low Temp.
Para 9.9.2 |
|
Permanence
Marking
Para 9.18 |
 |
|
 |
|
 |
|
 |
Electrical Measurements
Room Temp. Para 9.9.3 |
|
 |
|
 |
|
Terminal
Strength
Para 9.19 |
 |
|
 |
|
 |
|
 |
External Visual Inspection
Para 9.10 |
|
 |
|
External Visual
Inspection
Para 9.10 |
|
 |
 |
|
 |
|
 |
|
 |
| No failures allowed |
|
No failures allowed |
|
No failures allowed |
|
No failures allowed |
 |
|
 |
|
 |
|
 |
 |
|
 |
|
Level 3
Lot Acceptance |
 |
|
 |
|
 |
|
 |
 |
|
Level 2
Lot Acceptance |
 |
|
 |
|
|
|
|
Level 1
Lot Acceptance |
|
|
|
|
| |
1. Post burn-in electrical rejects may be used for this test
2. For distribution within the sample see para 8.2.2 |